  • Question 1 - International colour coding is used on medical gas cylinders. Other characteristics also play...

    Correct

    • International colour coding is used on medical gas cylinders. Other characteristics also play a role in determining the gas's identity within a cylinder.

      Which of the following options best describes a cylinder containing analgesics for obstetrics?

      Your Answer: Blue body, blue/white shoulder, full cylinder; 13700 KPa, gas mixture, requires a dual stage pressure regulator

      Explanation:

      The body of the Entonox cylinder is usually blue (occasionally white), with blue and white shoulders. Entonox contains a 50:50 mixture of oxygen and nitrous oxide, with a full cylinder pressure of 13700 KPa (137 bar). The cylinder is equipped with a two-stage pressure regulator for safe operation.

      The cylinder body and shoulder of nitrous oxide are (French) blue.

      In today’s anaesthetic workstations, carbon dioxide cylinders are no longer used.

      The body of an oxygen cylinder is black, with a white shoulder.

      The white Heliox (21 percent oxygen and 79 percent helium) cylinder has a brown and white shoulder. The administration of this gas mixture, which is less dense than air, is used to reduce turbulence (stridor) of inspiratory flow in patients with upper airway obstruction.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      32.8
      Seconds
  • Question 2 - For a rapid sequence induction of anaesthesia, you are pre-oxygenating a patient using...

    Correct

    • For a rapid sequence induction of anaesthesia, you are pre-oxygenating a patient using 100% oxygen and a fresh gas flow equal to the patient's minute ventilation.

      Which would be the most suitable choice of anaesthetic breathing system in this situation?

      Your Answer: Mapleson A system

      Explanation:

      The Mapleson A (Magill) and coaxial version of the Mapleson A system (Lack circuit) are more efficient for spontaneous breathing than any of the other Mapleson circuits. The fresh gas flow (FGF) required to prevent rebreathing is slightly greater than the alveolar minute ventilation (4-5 litres/minute). This is delivered to the patient through the outer coaxial tube and exhaust gases are moved to the scavenging system through the inner tube. In the Lack circuit, the expiratory valve is located close to the common gas outlet away from the patient end. This is the main advantage of the Lack circuit over the Mapleson A circuit.

      The Mapleson E circuit is a modification of the Ayres T piece and the FGF required to prevent rebreathing is 1.5-2 times the patient’s minute volume.

      The Bain circuit is the coaxial version of the Mapleson D circuit.

      The FGF for spontaneous respiration to avoid rebreathing is 160-200 ml/kg/minute.

      The FGF for controlled ventilation to avoid rebreathing is 70-100 ml/kg/min.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      25.5
      Seconds
  • Question 3 - Dinamap is an automated blood pressure monitoring device. Which of these statements best...

    Correct

    • Dinamap is an automated blood pressure monitoring device. Which of these statements best fit its properties?

      Your Answer: The cuff should be positioned at the same level as the heart

      Explanation:

      Dinamap continuously measures the systolic, diastolic and mean arterial pressure along with pulse rate, thereby providing a continuous monitoring of the blood pressure using the osscillitonometric principle of measurement.

      The device loses accuracy towards the extremes of BP and is more accurate with systolic compared with diastolic pressure. In arrhythmias such as AF, the devices are also inaccurate due to the major fluctuations associated with the individual pulse pressure variations.

      The manual BP device is still the gold standard for BP measurement and monitoring.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      23.2
      Seconds
  • Question 4 - Which statement most accurately describes the action of increasing the gain in ultrasound...

    Correct

    • Which statement most accurately describes the action of increasing the gain in ultrasound imaging?

      Your Answer: Amplifies the returning signal

      Explanation:

      A higher frequency ultrasound comes with a better resolution of the digital image. Ultrasound with a frequency of 15 MHz is best used in imaging of superficial organs such as the thyroid gland, muscles, tendons and breasts whereas deep organs are better imaged using a lower frequency of 2-7MHz because of its ability for deeper penetration but lower resolution. These low frequency probes are also used to diagnose ascites, pleural effusions or can be used in echocardiography.

      The US probe emits and then absorbs a reflected wave. Similar to brightness control, increasing the gain will amplify the return signal which is then attenuated by the tissue. This increases the signal to noise ratio.
      A high frame rate, which basically means the number of times an image is updated onto the screen per second, improves the resolution of a moving 3D image which has become more accurate as the computing power has increased.

      Widening of the image field can be obtained by altering the penetration depth which is obtained by changing the frequency of the US beam

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      11
      Seconds
  • Question 5 - From the following electromagnetic waves, which one has the shortest wavelength? ...

    Incorrect

    • From the following electromagnetic waves, which one has the shortest wavelength?

      Your Answer: Ultraviolet light

      Correct Answer: X rays

      Explanation:

      Electromagnetic waves are categorized according to their frequency or equivalently according to their wavelength. Visible light makes up a small part of the full electromagnetic spectrum.

      Electromagnetic waves with shorter wavelengths and higher frequencies include ultraviolet light, X-rays, and gamma rays. Electromagnetic waves with longer wavelengths and lower frequencies include infrared light, microwaves, and radio and televisions waves.

      Different electromagnetic waves according to their wavelength from shorter to longer are X-rays, ultraviolet radiations, visible light, infrared radiation, radio waves. X-ray among electromagnetic waves has the shortest wavelength and higher frequency with wavelengths ranging from 10*-8 to 10* -12 and corresponding frequencies.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      18
      Seconds
  • Question 6 - Regarding laminar gas flow, which of the following options has the most influence...

    Correct

    • Regarding laminar gas flow, which of the following options has the most influence on laminar flow?

      Your Answer: Diameter of tube

      Explanation:

      Laminar flow can be defined as the motion of a fluid where every particle in the fluid follows the same path of its previous particles. The following are properties of laminar flow of gas or fluids:

      1. Smooth unobstructed flow of gas through a tube of relatively uniform diameter
      2. Few directional changes
      3. Slow, steady flow through straight smooth, rigid, large calibre, cylindrical tube
      4. Outer layer flow slower than the centre due to friction, results in discrete cylindrical layers, or streamlines
      5. Double flow by doubling pressure as long as the flow pattern remains laminar

      Poiseuille’s Law relates the factors that determine laminar flow. It indicates the degree of resistance to fluid flow through a tube. The resistance to fluid flow through a tube is directly related to the length, flow and viscosity; and inversely related to the radius of the tube to the fourth power. This means that, when the radius is doubled, there is increase in flow by a factor of 16.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      10
      Seconds
  • Question 7 - You are preparing to anaesthetize a 27-year-old woman for an acute diagnostic laparoscopy...

    Incorrect

    • You are preparing to anaesthetize a 27-year-old woman for an acute diagnostic laparoscopy to rule out appendicitis.

      She has no medical history and does not take any medications on a regular basis. You're going to do a quick sequence induction.

      Which method of preoxygenation is the most effective and efficient?

      Your Answer: Mapleson A circuit with a fresh gas flow of 2-3 × minute volume

      Correct Answer: Mapleson A circuit with a fresh gas flow of 100 ml/kg

      Explanation:

      Professor Mapleson classified non-rebreathing circuits based on the position of the APL valve, which controls fresh gas flow.

      The Mapleson A (Magill) circuit is most effective in spontaneous breathing, requiring only 70-100 ml/kg (the patient’s minute volume) of fresh gas flow. The patient inhales fresh gas from the reservoir bag and tubing during inspiration. During expiration, the patient adds dead space gas (gas that hasn’t been exchanged) to the tubing and reservoir bag in addition to the fresh gas flow. At the patient’s end, alveolar gas is vented through the APL valve. During the expiratory pause, the fresh gas flow causes more gas to be released.

      The Mapleson A is inefficient during controlled ventilation. Venting occurs during inspiration rather than during the expiratory phase, as it does during spontaneous ventilation. As a result, unless a high fresh gas flow of >20 L/minute is used, alveolar gas is rebreathed.

      During spontaneous ventilation, the Mapleson D circuit is inefficient.

      The oxygen concentration in a Hudson mask is insufficient to allow for adequate pre-oxygenation.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      20.5
      Seconds
  • Question 8 - Which one of the following statement is true regarding United Kingdom gas cylinders?...

    Correct

    • Which one of the following statement is true regarding United Kingdom gas cylinders?

      Your Answer: Tensile tests are performed on sections of one cylinder in every hundred

      Explanation:

      Medical gas cylinders are made up of molybdenum steel but not cast iron. They are checked and assessed at a regular interval.

      At least one cylinder in each hundred are tested for tensile, pressure, smash, twist and straightening.

      Nitrous Oxide cylinders contain a mixture of liquid and vapour at a pressure of approx. 4500 kPa or 45 Bar. Carbon dioxide cylinder contain gas at the pressure of 5000kPa.

      The filling ratio is the ratio of mass of liquified gas in the cylinder to the mass of water required to fill the cylinder at the temperature of 15ºC. In the united kingdom, filling ratio of liquid nitrous oxide is 0.75. The cylinders are usually attached to the anaesthetic machine. As nitrous oxide is an N-methyl-d-aspartate receptor antagonist that may reduce the incidence of chronic post-surgical pain.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      27.8
      Seconds
  • Question 9 - Concerning the physical principles of temperature measurement by a thermocouple, which of the...

    Incorrect

    • Concerning the physical principles of temperature measurement by a thermocouple, which of the following best describes it?

      Your Answer: The semiconductor at the measuring end has a junction potential that is proportional to temperature

      Correct Answer: The bimetallic strip has a junction potential proportional to temperature

      Explanation:

      A thermocouple, or a thermal junction, is temperature measuring device consisting of a pair of dissimilar metal (bimetallic) wires or strips joined together. Typically, copper and constantan (an alloy of 55% copper and 45% nickel) are used. When there is contact between these metals, a small voltage is generated in the order of millivolts. The magnitude of the thermojunction electromotive force (emf) is proportional to applied temperature (the Seebeck effect). This physical principle is applied in the measurement of temperature. The electromotive force at the measuring junction is proportional to temperature.

      Two wires with different coefficients of expansion, joined together, can be used as a switch for thermostatic control.

      Semiconductors are NOT used in thermocouple. The resistance of the measuring junction of a thermocouple is irrelevant.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      25
      Seconds
  • Question 10 - The equipment used for patient monitoring in theatre and intensive care settings have...

    Incorrect

    • The equipment used for patient monitoring in theatre and intensive care settings have electrical safety requirements for the protection of hospital staff and patients.
      Of the different classes of electrical equipment listed, which is least likely to cause a patient to suffer a microshock?

      Your Answer: III

      Correct Answer: II (CF)

      Explanation:

      Microshock refers to ventricular fibrillation caused by miniscule amounts of currents or voltages (100-150 microamperes) passing through the myocardial tissue from external cables arising from electrical components within the cardiac muscle, for example, pacemaker electrodes or saline filled venous catheters.
      The risk of shock changes with the construction of electrical equipment in question. The main classes of electrical equipment include: I: Appliances have a protective earth connected to an outer casing which prevents live elements from coming in contact with conductive elements. A fault in this equipment class will result in live elements coming in contact with the outer casing and allowing electrical flow into the protective earth. This triggers the protective fuse to disconnect the electric supply to the appliance.
      II: These appliances have reinforced insulation. In the event of a fault which causes the first layer of insulation to fail, the second layer is able to prevent contact of live elements with outer casing.
      III: These appliances have no insulation to provide safety, and rely solely on the use of separated extra low voltage source (SELV) which limits voltage to 25V AC or 60V DC allowing for a person to come in contact with it without risk of a shock under normal dry conditions. Under wet conditions, voltage supply should be lowered to reduce risk of shock. These devices have no risk of macroshocks, but some risk of microshocks.
      Class I and II electrical appliances are further divided into subtypes developed to limit current leakage in the event of a singular fault:
      B (body): Upper limit of current leakage is 500 µA. This current can cause skin tingling and microshocks, but is not sufficient to cause injury.
      BF (body floating): These appliances have an isolating capacitor or transformer which separate the secondary circuit from the protective earth. The upper limit of current leakage is the same as type B.
      CF (cardiac floating): Upper limit of leakage current during a singular fault is 50 microamps. It is least likely to result in a microshock

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      22.4
      Seconds
  • Question 11 - Regarding a paramagnetic oxygen analyser, the following statements are TRUE: ...

    Incorrect

    • Regarding a paramagnetic oxygen analyser, the following statements are TRUE:

      Your Answer: Can be used to measure the concentration of diamagnetic gases

      Correct Answer: Utilises null deflection

      Explanation:

      The electrons in the outer shell of an oxygen molecule are unpaired, thus it has paramagnetic properties and is attracted into a magnetic field.

      It utilizes null deflection -True
      Null deflection is a crucial principle in paramagnetic analysers (reflected beam of light on two photocells) which gives very accurate results (typically 0.1%).

      It can be used to measure the concentration of diamagnetic gases – False
      Since most other gases are weakly diamagnetic they are repelled by a magnetic field (nitric oxide is also paramagnetic).

      Can measure gases dissolved in the blood – False
      For accurate analysis the sample gas must be dried before passing into the analysis cell, for example, by passage through silica gel. Therefore, they are unsuitable to measure gases dissolved in blood.

      Does not require calibration – False
      As with most measurement instruments paramagnetic analysers must be calibrated before use.

      E) The readings are unaffected by water vapour – False
      Water vapour affects the readings hence for accurate analysis the sample gas must be dried before passing into the analysis cell, for example, by passage through silica gel. That is why they are unsuitable to measure dissolved blood gases.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      42.5
      Seconds
  • Question 12 - Which of the following is true about the pulse oximeter? ...

    Incorrect

    • Which of the following is true about the pulse oximeter?

      Your Answer: Detect real-time oxygen saturation

      Correct Answer: Is accurate to within +/- 2% in the range of 70% to 100% saturation

      Explanation:

      The pulse oximeter provides a continuous non-invasive measurement of the arterial oxygen saturation. The light emitting diodes (LEDs) produce beams of red and infrared light at 660 nm and 940 nm respectively (not 640 and 960 nm), which travel through a finger (toe, ear lobe or nose) and are then detected by a sensitive photodetector.

      The light absorbed by non-pulsatile tissues is constant (DC), and the non-constant absorption (AC) is the result of arterial blood pulsation. The DC and AC components at 660 and 940 nm are then analysed by the microprocessor and the result is related to the arterial saturation.

      An isosbestic point is a point at which two substances absorb a wavelength of light to the same degree. In pulse oximetry the different absorption profiles of oxyhaemoglobin and deoxyhaemoglobin are used to quantify the haemoglobin saturation (in %). Isosbestic points occur at 590 and 805 nm (not 490 and 805 nm), where the light absorbed is independent of the degree of saturation, and are used as reference points.

      The pulse oximeter is accurate to within +/- 2% in the range of 70% to 100% saturation, and below 70% the readings are extrapolated. Pulse oximeters average their readings every 10 to 20 seconds and thus they cannot detect acute desaturation events. Consequently, they are often referred to as ‘lag’ monitors, due to the time delay in identifying the desaturation episode.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      114.3
      Seconds
  • Question 13 - Regarding the emergency oxygen flush, which is true? ...

    Correct

    • Regarding the emergency oxygen flush, which is true?

      Your Answer: May lead to awareness if used inappropriately

      Explanation:

      When the emergency oxygen flush is pressed, 100% oxygen is supplied from the common gas outlet. This gas bypasses BOTH flowmeters and vaporisers. The flow of oxygen is usually 45 l/min at a PRESSURE OF 400 kPa.

      There is an increased risk of pulmonary barotrauma when the emergency flush is pressed, especially when anaesthetising paediatric patients.

      The inappropriate use of the flush causes dilution of anaesthetic gases and this increases the possibility of anaesthetic awareness .

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      78.6
      Seconds
  • Question 14 - Health workers are at increased risks of anaesthetic exposure. Therefore, The Control of...

    Correct

    • Health workers are at increased risks of anaesthetic exposure. Therefore, The Control of Substances Hazardous to Health (COSHH) regulations require measures implemented to assess and control the risks related to this exposure.

      Among the following control measures, which one is most likely to limit potentially harmful exposure to anaesthetic agents within an operating theatre?

      Your Answer: Total intravenous anaesthesia (TIVA)

      Explanation:

      Exposure to anaesthetic hazards is one among the occupational exposures in manipulating toxic agents or inhaling toxic gases during anaesthetic practices.

      Toxic gases mainly nitrous oxide, is one of the most gaseous anaesthetic agents that constitutes an important source of pollution. One of the safe and effective technics used in anaesthesia and reducing the amount of pollution is the Total Intravenous Anaesthesia (TIVA) which consists of using opioids in analgesia and propofol for the induction and the maintenance of anaesthesia. It refers to the administration intravenously of an anaesthetic, sedative, and/or tranquilizer. A less polluting but not the best way to get rid of the toxic aesthetic agents is the scavenger system that collects and expels the gas outside the medical environment. Yet, this technique still represents a hazard for the environment and still increase the risk of exposure for the health workers and clinical staff.

      Fume cupboards are also not recommended to use because of their high pollution potency, mainly of the air resulting in a great harm for medical workers.

      Supraglottic airways as well as the Air Changes per Hour technics could be harmful for both patients and health workers, increasing the risks of transmitted diseases, namely nosocomial infections.

      Therefore, the Total Intravenous Anaesthesia technique (TIVA) is most likely to be safe and recommended to use.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      35.7
      Seconds
  • Question 15 - Which medical gas cylinders have the correct colour codes? ...

    Correct

    • Which medical gas cylinders have the correct colour codes?

      Your Answer: Oxygen cylinders have a black body with white shoulders

      Explanation:

      The following are the colour codes for medical gas cylinders:

      Oxygen cylinder has a dark body with white shoulders.

      Nitrous oxide is French blue. Air encompasses a grey body with dark and white quarters on the shoulders.

      Entonox contains a French blue body with white and blue quarters on the shoulders.

      Carbon dioxide barrels are grey in colour.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      27.3
      Seconds
  • Question 16 - An emergency appendicectomy is being performed on a 20 year old man. For...

    Correct

    • An emergency appendicectomy is being performed on a 20 year old man. For maintenance of anaesthesia, he is being ventilated using a circle system with a fresh gas flow (FGF) of 1 L/min (air/oxygen and sevoflurane). The trace on the capnograph shows a normal shape.

      The table below demonstrates the changes in the end-tidal and baseline carbon dioxide measurements of the capnograph at 10 and 20 minutes of anaesthesia maintenance.  
      End-tidal CO2: 4.9 kPa vs 8.4kPa (10 minutes vs 20 minutes)
      Baseline end-tidal CO2: 0.2 kPa vs 2.4kPa

      Pulse 100-107 beats per minute, systolic blood pressure 125-133 mmHg and oxygen saturation 98-99%. 

      Which of the following is the single most important immediate course of action?

      Your Answer: Increase the FGF

      Explanation:

      End-tidal carbon dioxide (ETCO2) monitoring has been an important factor in reducing anaesthesia-related mortality and morbidity. Hypercarbia, or hypercapnia, occurs when levels of CO2 in the blood become abnormally high (Paco2 >45 mm Hg). Hypercarbia is confirmed by arterial blood gas analysis. When using capnography to approximate Paco2, remember that the normal arterial–end-tidal carbon dioxide gradient is roughly 5 mm Hg. Hypercarbia, therefore, occurs when PETco2 is greater than 40 mm Hg.

      The most likely explanation for the changes in capnograph is either exhaustion of the soda lime and a progressive rise in circuit dead space.

      Inspect the soda lime canister for a change in colour of the granules. To overcome soda lime exhaustion, the first step is to increase the fresh gas flow (FGF) (Option A). Then, if need arises, replace the soda lime granules. Other strategies that can work are changing to another circuit or bypassing the soda lime canister, but remember that both these strategies are employed only after increasing FGF first. Exclude other causes of equipment deadspace too.

      There are also other causes for hypercarbia to develop intraoperatively:
      1. Hypoventilation is the most common cause of hypercapnia. A. Inadequate ventilation can occur with spontaneous breathing due to drugs like anaesthetic agents, opioids, residual NMDs, chronic respiratory or neuromuscular disease, cerebrovascular accident.
      B. In controlled ventilation, hypercapnia due to circuit leaks, disconnection or miscalculation of patient’s minute volume.
      2. Rebreathing – Soda lime exhaustion with circle, inadequate fresh gas flow into Mapleson circuits and increased breathing system deadspace.
      3. Endogenous source – Tourniquet release, hypermetabolic states (MH or thyroid storm) and release of vascular clamps.
      4. Exogenous source – Absorption of CO2 from pneumoperitoneum.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      91.1
      Seconds
  • Question 17 - A 240 volt alternating current (AC) socket from a wall is used to...

    Correct

    • A 240 volt alternating current (AC) socket from a wall is used to charge a direct current (DC) cardiac defibrillator.

      Name the electrical component that converts AC to DC.

      Your Answer: Rectifier

      Explanation:

      There are two types of defibrillators
      AC defibrillator
      DC defibrillator

      AC defibrillator,
      consists of a step-up transformer with primary and secondary winding and two switches. Since secondary coil consists of more turns of wire than the primary coil, it induces larger voltage. A voltage value ranging between 250V to 750V is applied for AC external defibrillator. And used to enable the charging of a capacitor.

      DC defibrillator,
      consists of auto transformer T1 that acts as primary of the high voltage transformer T2. Is an iron core that transfers energy between 2 circuits by electromagnetic induction. Transformers are used to isolate circuits, change impedance and alter voltage output. transformers do not convert AC to DC.

      Diode rectifier composed of 4 diodes made of semiconductor material allows current to flow only in one direction. Alternating current (AC) passing through these diodes produces direct current (DC). Capacitor stores the charge in the form of an electrostatic field.

      Capacitor is used to convert the rectified AC voltage to produce DC voltage but capacitors do not directly convert AC to DC.

      Inductor induces a counter electromotive force(emf) that reduces the capacitor discharge value.

      In step-down transformer primary coils has more turns of wire than secondary coil, so induced voltage is smaller in the secondary coil.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      23.5
      Seconds
  • Question 18 - Prior to rapid sequence induction of anaesthesia, a man with a BMI of...

    Correct

    • Prior to rapid sequence induction of anaesthesia, a man with a BMI of 35 is pre-oxygenated.

      Which method of pre-oxygenation with a tight-fitting face mask is the most effective?

      Your Answer: Oxygen 6 litres per minute via a Mapleson A breathing system, with patient sitting up at 30 degrees breathing four vital capacity breaths

      Explanation:

      This patient is morbidly obese and has a high risk of developing hypoxia. This will be exacerbated by the patient’s supine position, as a result of:

      Functional residual capacity has been reduced (FRC)
      Increased closing capacity (CC)
      Reduced tidal volume due to increased airway resistance, decreased thoracic cage compliance, and decreased respiratory muscle strength and endurance
      Following induction of general anaesthesia, there is a tendency for atelectasis and increased O2 consumption due to the increased workload of respiratory muscles and the overall increase in metabolism.

      Pre-oxygenation with 100 percent oxygen via a tight-fitting mask can be done using either tidal volume breaths for three to five minutes or four vital capacity breaths in normal circumstances. In the head-up position, this patient is much more likely to be adequately pre-oxygenated, maximising the FRC and minimising the CC. In spontaneously breathing patients, the Mapleson A and circle systems are both effective, but the Mapleson D requires 160-200 ml/kg/minute to prevent rebreathing.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      112.1
      Seconds
  • Question 19 - What feature is found in the flowmeters of modern anaesthetic machines ? ...

    Correct

    • What feature is found in the flowmeters of modern anaesthetic machines ?

      Your Answer: The use of stannic oxide increases the accuracy of flowmeters

      Explanation:

      Flowmeters measure the rate at which a specific gas, that the flowmeter has been calibrated for, passes through. This calibration is done at room temperature and standard atmospheric pressure with an accuracy of +/- 2%.

      Reading the flowmeter is done from the top of a bobbin (the midpoint of a ball). Oxygen is the last gas to be added downstream to the mixture delivered to the back bar as a safety feature. This prevents delivery of a hypoxic mixture.

      Inaccurate flow measurements occur when the bobbin sticks to the inside wall of the flowmeter. Stannic oxide has been used as a successful antistatic substance thus, reducing the aforementioned risk.

      Carbon dioxide being easily delivered is found on some older machines, but those attached flowmeters are limited by a maximum flow of 500 ml /min. Thus avoiding the delivery of a hypercarbic mixture.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      42.7
      Seconds
  • Question 20 - A strain gauge operates on which of the following principles? ...

    Correct

    • A strain gauge operates on which of the following principles?

      Your Answer: Varying resistance of a wire when stretched

      Explanation:

      The principle by which a strain gauge works is that when a wire is stretched, it becomes longer and thinner, and as a result, its resistance increases.

      A strain gauge, which is used in pressure transducers, acts as a resistor. When the pressure in a pressure transducer changes, the diaphragm moves, changing the tension in the resistance wire and thus changing the resistance.

      Changes in current flow through the resistor are amplified and displayed as a pressure change measure.

      A Wheatstone bridge, on the other hand, is frequently used to measure or monitor these changes in resistance.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      8
      Seconds
  • Question 21 - Many of the processes we deal with in anaesthesia entail a relationship between...

    Correct

    • Many of the processes we deal with in anaesthesia entail a relationship between two or more variables.

      Which of the following relationships is a linear relationship?

      Your Answer: The relationship between the junction potential and temperature in a thermocouple

      Explanation:

      Two bonded wires of dissimilar metals, iron/constantan or copper/constantan, make up a thermocouple (constantan is an alloy of copper and nickel). At the tip, a thermojunction voltage is generated that is proportional to temperature (Seebeck effect).

      All of the other connections are non-linear.

      For a single compartment model, the relationship between a decrease in plasma concentration of an intravenous bolus of a drug and time is a washout exponential.

      A sine wave is the relationship between current and degrees or time from a mains power source.

      A sigmoid curve represents the relationship between efficacy and log-dose of a pure agonist on mu receptors.

      The pressure of a fixed mass of gas and its volume (Boyle’s law) at a fixed temperature are inversely proportional, resulting in a hyperbolic curve.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      374.9
      Seconds
  • Question 22 - Which of the following is correct for gas pipeline pressure? ...

    Incorrect

    • Which of the following is correct for gas pipeline pressure?

      Your Answer: 4 bar for oxygen

      Correct Answer:

      Explanation:

      Pipeline gases (in the UK this includes: Oxygen, Nitrous oxide, Medical air, and Entonox) are supplied at 4 bar (or 400 kPa), and compressed air is supplied at 7 bar for power tools.

      Carbon dioxide and nitric oxide are usually only supplied in cylinders.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      9.9
      Seconds
  • Question 23 - Regarding anaesthetic breathing circuits, which one would be the best for spontaneous breathing?...

    Incorrect

    • Regarding anaesthetic breathing circuits, which one would be the best for spontaneous breathing?

      Your Answer: Bain circuit

      Correct Answer: Lack circuit

      Explanation:

      Among the breathing circuits, the Lack circuit is the most efficient for spontaneous breathing.

      An outer coaxial tube is present to deliver fresh air; exhaust air is routed to an inner tube, which is then delivered to a scavenging system. An expiratory valve is seen at the patient end, which is an advantage over other circuits. Moreover, the Lack circuit prevents rebreathing slightly greater than the alveolar minute ventilation at 4-5 litres per minute.

      The Bain circuit prevents rebreathing at 160-200ml/kg per minute, and is a co-axial version of the Mapleson D circuit.

      The Mapleson E circuit prevent rebreathing at a fresh gas flow (FGF) of approximately twice the patient’s normal minute volume. A modification of this, the Mapleson F, has a reservoir bag at the opposite end for the FGF. This circuit is appropriate for paediatric patients with a body weight less than 20 kg.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      19
      Seconds
  • Question 24 - A sevoflurane vaporiser with a 2 percent setting and a 200 kPa ambient...

    Incorrect

    • A sevoflurane vaporiser with a 2 percent setting and a 200 kPa ambient pressure is used.

      At this pressure, which of the following options best represents vaporiser output?

      Your Answer: The output is 2% because the saturated vapour pressure of sevoflurane is unaffected by ambient pressure

      Correct Answer: The output is 1% because the saturated pressure of sevoflurane is unaffected by ambient pressure

      Explanation:

      Ambient pressure has no effect on a volatile agent’s saturated vapour pressure (SVP). At a temperature of 20°C, the SVP of sevoflurane is approximately 21 kPa, or 21% of atmospheric pressure (100 kPa).

      The SVP of sevoflurane remains the same when the ambient pressure is doubled to 200 kPa, but the output of the vaporiser is halved, now 21 percent of 200 kPa, equalling 10.5 percent. The vaporiser’s output has increased to 1%, but the partial pressure output has remained unchanged. The splitting ratio will not change because it is determined by temperature changes.

      Calculations can be made as follows:

      Vaporizer output % (ambient pressure) = % volatile (calibrated) x 100 kPa calibrated pressure/ambient pressure
      2% = 2% (dialled) × 100/100
      2% of 100 = 2 kPa

      Altitude, pressure 50 kPa
      4% = 2% (dialled) × 100/50
      4% of 50 = 2 kPa

      High pressure at 200 kPa
      1% = 2% (dialled) × 100/200
      1% of 200 = 2 kPa

      Sevoflurane has a boiling point of 58°C and, unlike desflurane (which has a boiling point of 22.8°C), does not need to be heated and pressurised with a Tec 6 vaporiser.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      81.4
      Seconds
  • Question 25 - A current flows through a simple electric circuit.

    Which of the following electrical component...

    Correct

    • A current flows through a simple electric circuit.

      Which of the following electrical component configurations has the greatest potential difference?

      Your Answer: Two 5 ohm resistors in series with a passing current of 10 ampere

      Explanation:

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      137.7
      Seconds
  • Question 26 - Which of the following statements is TRUE regarding an epidural set? ...

    Incorrect

    • Which of the following statements is TRUE regarding an epidural set?

      Your Answer: The distal end of the catheter has an open rounded tip and two or more side ports

      Correct Answer: 19G Tuohy needles have 0.5 cm markings

      Explanation:

      A paediatric 19G Tuohy catheter is available that is 5cm in length and has 0.5cm markings

      18G Tuohy catheters are generally 9 to 10cm to hub

      Distal end of catheter is angled (15 to 30 degrees) and closed to avoid puncturing the dura

      Epidural mesh are usually 0.2 microns and are used to filter bacteria and viruses to ensure sterility of procedure

      Transparent catheters are 90cm long with diameters depending on gauge size. It has 1cm graduations from 5 to 20cm to ensure they have been inserted amply and removed completely. Distal end is smooth which can be open or closed (with lateral openings)

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      29
      Seconds
  • Question 27 - When compared to unipolar diathermy, which of the following is more specific to...

    Incorrect

    • When compared to unipolar diathermy, which of the following is more specific to bipolar diathermy?

      Your Answer: Requires an isolating capacitor

      Correct Answer: Has a power output of up to 140 joules per second

      Explanation:

      Electrocautery, also known as diathermy, is a technique for coagulation, tissue cutting, and fulguration that uses a high-frequency current to generate heat (cell destruction from dehydration).

      The two electrodes in bipolar diathermy are the tips of forceps, and current passes between the tips rather than through the patient. Bipolar diathermy’s power output (40-140 W) is lower than unipolar diathermy’s typical output (400 W). There is no earthing in the bipolar circuit.

      A cutting electrode and a indifferent electrode in the form of a metal plate are used in unipolar diathermy. The high-frequency current completes a circuit by passing through the patient from the active electrode to the metal plate. When used correctly, the current density at the indifferent electrode is low, and the patient is unlikely to be burned. Between the patient plate and the earth is placed an isolating capacitor. This has a low impedance to a high frequency current, such as diathermy current, and is used in modern diathermy machines. The capacitor has a high impedance to current at 50 Hz, which protects the patient from electrical shock.

      High frequency currents (500 KHz – 1 MHz) are used in both unipolar and bipolar diathermy, which can cause tissue damage and interfere with pacemaker function (less so with bipolar diathermy).

      The effect of diathermy is determined by the current density and waveform employed. The current is a pulsed square wave pattern in coagulation mode and a continuous square wave pattern in cutting mode.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      37.5
      Seconds
  • Question 28 - All of the following statements about pH electrode are incorrect except: ...

    Incorrect

    • All of the following statements about pH electrode are incorrect except:

      Your Answer: The reference electrode has pH sensitive glass

      Correct Answer: A semi-permeable membrane reduces protein contamination

      Explanation:

      Pulse oximeters combine the principles of oximetry and plethysmography to noninvasively measure oxygen saturation in arterial blood. A sensor containing two or three light emitting diodes and a photodiode is placed across a perfused body part, commonly a finger, to be transilluminated. Oximetry depends on oxyhaemoglobin and deoxyhaemoglobin, and their ability to absorb the beams of light produced by the light emitting diodes: red light at 660 nm and infrared light at 960 nm.

      The isosbestic point is the point wherein two different substances absorb light to the same extent. For oxyhaemoglobin and deoxyhaemoglobin, the points are at 590 nm and 805 nm. These are considered reference points where light absorption is independent of the degree of saturation.

      Non-constant absorption of light is often due to the presence of an arterial pulsation, whilst constant absorption of light is seen in non-pulsatile tissues.

      Most pulse oximeters are inaccurate at low SpO2, but is accurate at +/- 2% within the range of 70% to 100% SpO2. All pulse oximeters demonstrate a delay in between changes in SaO2 and SpO2, and display average readings every 10 to 20 seconds, hence they are unable to detect acute desaturation episodes.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      38.2
      Seconds
  • Question 29 - Which of the following statements is true regarding the Wrights Respirometer? ...

    Incorrect

    • Which of the following statements is true regarding the Wrights Respirometer?

      Your Answer: May over-read at low flows

      Correct Answer: Measures the minute volume to within an accuracy of +/- 10%

      Explanation:

      A Wrights Respirometer measures the volume of air exhaled over the course of one minute of normal breathing

      It is unidirectional and measures tidal volume and minute volume of gas flow in one direction. It is placed at the expiratory side (lower pressure than inspiratory side therefore lower chances of gas leaks)

      Slits are arranged such that incoming gas will rotate the vane at a rate of 150 revolutions per litre of flowing gas

      The Wright respirometer tends to over-read at high flow rates and under-read at low flows because of mechanical causes like friction and inertia and the accumulation of water vapour

      The ideal flow for accurate readings is 2 L/min for the respirometer. The respirometer reads the tidal volume and minute volume with a ±5–10% accuracy within the range of 4–24 L/min.

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus
      27.9
      Seconds
  • Question 30 - With respect to the peripheral nerve stimulators, which one is used to perform...

    Incorrect

    • With respect to the peripheral nerve stimulators, which one is used to perform nerve blocking?

      Your Answer: Require three connection leads for the skin, needle and the earth

      Correct Answer:

      Explanation:

      The nerve stimulators deliver a stimulus lasting for 1-2 milliseconds (not second) to perform nerve blockage.

      There are just 2 leads (not 3); one for the skin and other for the needle.

      Prior to the administration of the local anaesthesia, a current of 0.25 – 0.5 mA (not 1-2mA) at the frequency of 1-2 Hz is preferred.

      If the needle tip is close to the nerve, muscular contraction could be possible at the lowest possible current.

      Insulated needles have improved the block success rate, as the current is only conducting through needle tip.

      Stimulus to the femoral nerve which is placed in the mid lingual line causes withdrawer of the quadriceps and knee extension, that’s the dancing patella ( not plantar flexion).

    • This question is part of the following fields:

      • Anaesthesia Related Apparatus